search

PyroScience Sensors

Filter Optionsi

Oxygen Sensor Cap

APHOX-S-OXCAP

  • Oxygen Sensor Caps
  • For immersion probe APHOX-S-O2
  • For measurement of dissolved oxygen (DO)
  • Packaging unit = 2 pcs.

Fixed Fiber pH Minisensor

PHF500-PK6.5

  • Measurement range pH 5.5 - 7.5
  • Fixed in a needle, tip protruding 5mm
  • Tip diameter 500µm
  • for fast pH measurements (t90 at 25°C < 10 sec)
  • Without optical isolation

Fixed Fiber pH Minisensor

PHF500-PK8

  • Measurement range pH 7.0 - 9.0
  • Fixed in a needle, tip protruding 5mm
  • Tip diameter 500µm
  • for fast pH measurements (t90 at 25°C < 10 sec)
  • Without optical isolation

Robust Oxygen Probe

OXROB10

  • Stainless steel 10cm long, 3mm in diameter
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)
  • Negligible drift, >3 years shelf time

Insertable Oxygen Miniprobe

OXIMP500

  • Bare Optical fiber 500 µm in diameter
  • Enlarged sensing surface over 3-5mm length at the sensor tip
  • For measurements of smoothed oxygen levels in samples with micro-heterogeneities

High Speed Robust Oxygen Probe

OXROB10-HS

  • Robust probe for fast measurements
  • Stainless steel 10cm long, 3mm in diameter
  • High speed oxygen sensor (T90 < 0.5s gas,< 3s water)
  • Works in gas (%oxygen) and liquids (DO)
  • Optically Isolated, usable in photosynthetic samples

Insertable Oxygen Miniprobe

OXIMP1000

  • Bare Optical fiber 1000 µm in diameter
  • Enlarged sensing surface over 3-5mm length at the sensor tip
  • For measurements of smoothed oxygen levels in samples with micro-heterogeneities

Insertable Oxygen Miniprobe

OXIMP250

  • Bare Optical fiber 250 µm in diameter
  • Enlarged sensing surface over 3-5mm length at the sensor tip
  • For measurements of smoothed oxygen levels in samples with micro-heterogeneities

Robust Screw Cap Oxygen Probe

OXROBSC

  • Robust probe with 2 oxygen screw cap sensors
  • Stainless steel 10cm long, 4mm in diameter
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)

Retractable Fiber Oxygen Microsensor

OXR50

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Robust Oxygen Probe

OPROB3

  • Stainless steel 3cm long, 3mm in diameter
  • 1m fiber length, PICO-connector
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)
    ******will be discontinued on 1st April 2024*********
     

Robust Screw Cap Oxygen Probe

OXROBGSC-CL5

  • Robust screw probe with 2 oxygen screw caps
  • Stainless steel 10cm long, 4mm in diameter
  • 5m cable length (-CL5)
  • Works in gas (%oxygen) and liquids (DO)
  • Optically isolated (-OI)

Protected Tip Oxygen Minisensor

OXF500PT

  • Sensor tip protect by needle
  • Needle diameter 500µm
  • Optimized for measurements in gas
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Oxygen Sensor Spots

OXSP5

  • Sensor spots (8 pcs.) 5mm in diameter
  • Autoclavable (few times, short cycle)
  • Works in gas (%oxygen) and in liquids (DO)
  • No oxygen consumption
  • Negligible drift >3 years shelf life

Self-Adhesive Oxygen Sensor Spots

OXSP5-ADH

  • Self-adhesive sensor spots (8 pcs.) 5mm in diameter
  • For measurements in closed containers
  • Works in gas (%oxygen) and in liquids (DO)
  • No oxygen consumption
  • Negligible drift >3 years shelf life

Self-Adhesive Sterilized Oxygen Sensor Spots

OXSP5-ADH-STER

  • Self-adhesive sensor spots (8 pcs.) 5mm in diameter
  • Sterilized using 25kGy beta-irradiation
  • For measurements in closed containers
  • Works in gas (%oxygen) and in liquids (DO)

pH Sensor Spots

PHSP5-PK7

  • Sensor spots (8 pcs.) 5mm in diameter
  • For measurements in closed containers
  • Precalibrated for plug & play measurements
  • Contamination-free non-invasive measurement
  • Autoclavable

Self-Adhesive pH Sensor Spots

PHSP5-PK7-ADH

  • Self-adhesive sensor spots (8 pcs.) 5mm in diameter
  • For measurements in closed containers
  • Precalibrated for plug & play measurements
  • Contamination-free non-invasive measurement
  • Autoclavable

Self-Adhesive Sterilized pH Sensor Spots

PHSP5-PK7-ADH-STER

  • Self-adhesive sensor spots (8 pcs.) 5mm in diameter
  • Sterilized using 25kGy beta-irradiation
  • Precalibrated for plug & play sterile measurements
  • Contamination-free non-invasive measurement

Robust Oxygen Dipping Probe

OPDIP20

  • Stainless steel 20cm long, 3mm in diameter
  • PICO-connector
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)
    ******will be discontinued on 1st April 2024*********

pH Sensor Spots

PHSP5-PK8

  • Sensor spots (8 pcs.) 5mm in diameter
  • For measurements in closed containers
  • Precalibrated for plug & play measurements
  • Contamination-free non-invasive measurement
  • Autoclavable

Self-Adhesive pH Sensor Spots

PHSP5-PK8-ADH

  • Self-adhesive sensor spots (8 pcs.) 5mm in diameter
  • For measurements in closed containers
  • Precalibrated for plug & play measurements
  • Contamination-free non-invasive measurement
  • Autoclavable

pH Sensor Spots

PHSP5-PK5

  • Sensor spots (8 pcs.) 5mm in diameter
  • For measurements in closed containers
  • Precalibrated for plug & play measurements
  • Contamination-free non-invasive measurement
  • Autoclavable

pH Sensor Spots

PHSP5-PK6

  • Sensor spots (8 pcs.) 5mm in diameter
  • For measurements in closed containers
  • Precalibrated for plug & play measurements
  • Contamination-free non-invasive measurement
  • Autoclavable

pH Sensor Spots

PHSP5-PK8T

  • Sensor spots (8 pcs.) 5mm in diameter
  • For marine measurements on pH total scale
  • For measurements in closed containers
  • Precalibrated for plug & play measurements
  • Contamination-free non-invasive measurement

Self-Adhesive pH Sensor Spots

PHSP5-PK5-ADH

  • Self-adhesive sensor spots (8 pcs.) 5mm in diameter
  • For measurements in closed containers
  • Precalibrated for plug & play measurements
  • Contamination-free non-invasive measurement
  • Autoclavable

Self-Adhesive pH Sensor Spots

PHSP5-PK6-ADH

  • Self-adhesive sensor spots (8 pcs.) 5mm in diameter
  • Precalibrated for plug & play measurements
  • Contamination-free non-invasive measurement
  • Autoclavable

Self-Adhesive pH Sensor Spots

PHSP5-PK8T-ADH

  • Self-adhesive sensor spots (8 pcs.) 5mm in diameter
  • For marine measurements on pH total scale
  • Precalibrated for plug & play measurements
  • Contamination-free non-invasive measurement

Oxygen Nanoprobes

OXNANO

  • Dispersible oxygen nanoparticles
  • Ideal for microfluidics or lab-on-a-chip
  • For measurement in complex geometries
  • Autoclavable (few times, short cycle)
  • Real-time response

Oxygen Monitoring in Organic Solvents

OXSOLV

  • Works in many polar and nonpolar solvents
  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Needle diameter/ length: 1.5mm / 150mm
  • No oxygen consumption

Robust Screw Cap Oxygen Probe

OXROBGSC-CL10

  • Robust screw probe with 2 oxygen screw caps
  • Stainless steel 10cm long, 4mm in diameter
  • 10m cable length (-CL10)
  • Works in gas (%oxygen) and liquids (DO)
  • Optically isolated (-OI)

Robust Screw Cap Oxygen Probe

OXROBGSC-CL20

  • Robust screw probe with 2 oxygen screw caps
  • Stainless steel 10cm long, 4mm in diameter
  • 20m cable length (-CL20)
  • Works in gas (%oxygen) and liquids (DO)
  • Optically isolated (-OI)

Sterile Oxygen Flow-Through Cell

OXFLOW

  • Flow-through cell with integrated optical oxygen sensor
  • Sterilized using 25kGy beta-irradiation
  • Luer lock adapters for ca. 3.2 or 4.8 mm ID tubings
  • Works in gas (%oxygen) and liquids (DO)

Sterile Oxygen Flow-Through Cell

OXFLOW-HS

  • Flow-through cell with integrated optical oxygen sensor
  • Sterilized using 25kGy beta-irradiation
  • Luer lock adapters for 3.2 or 4.8 mm ID tubings
  • Works in gas (%oxygen) and liquids (DO)
  • High speed response time (t90 < 1s)

Sterile Trace Range Oxygen Flow-Through Cell

TROXFLOW

  • Flow-through cell with integrated optical oxygen sensor
  • Sterilized using 25kGy beta-irradiation
  • Luer lock adapters for ca. 3.2 or 4.8 mm ID tubings
  • Works in gas (%oxygen) and liquids (DO)
  • For high precision measurements close to 0% oxygen

Sterile Temperature Flow-Through Cell

TPFLOW

  • Flow-through cell with integrated optical temperature sensor
  • Luer-lock T-Connector with removable temperature mini probe
  • Sterilized using 25kGy beta-irradiation
  • Luer lock adapters for ca. 3.2 or 4.8 mm ID tubings

Oxygen & Temperature Flow-Through Cell

TOFTC2

  • With contactless oxygen & temp sensor
  • For ca. 3.2 or 4.0 mm ID tubings
  • Recommended flow rate: 20-500 mL/min
  • Measurement range temp 0°C - 50°C

Oxygen Flow-Through Cell

OXFTC

  • With integrated contactless optical oxygen sensor
  • Luer-lock with tubing adapters
  • For ca. 1.6 or 2.4 mm ID tubings
  • Recommended flow rate: 10-100 mL/min

Oxygen & Temperature Respiration Vial

TOVIAL20

  • 20 ml vial with integrated oxygen & temp sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measures oxygen gas (%oxygen) or dissolved oxygen (DO)
  • Measurement range temp 0°C - 50°C
  • True temperature compensation possible

Oxygen & pH & Temperature Vial

PHTOVIAL20-PK7

  • 20 ml vial with integrated pH + temp + oxygen sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measurement range pH 6.0-8.0
  • Measurement range temp 0°C - 50°C
  • True temperature compensation

Oxygen & pH & Temperature Vial

PHTOVIAL20-PK8

  • 20 ml vial with integrated pH + temp + oxygen sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measurement range pH 7.0-9.0
  • Measurement range temp 0°C - 50°C
  • True temperature compensation

Sterile pH Flow Through Cell

PHFLOW-PK7

  • Flow-through cell with integrated optical pH sensor
  • Luer-lock T-Connector with removable pH mini probe
  • Precalibrated for plug & play sterile measurements
  • Sterilized using 25kGy beta-irradiation
  • Luer lock adapters for ca. 3.2 or 4.8 mm ID tubings

Sterile pH Flow Through Cell

PHFLOW-PK8

  • Flow-through cell with integrated optical pH sensor
  • Luer-lock T-Connector with removable pH mini probe
  • Precalibrated for plug & play sterile measurements
  • Sterilized using 25kGy beta-irradiation
  • Luer lock adapters for ca. 3.2 or 4.8 mm ID tubings

Sterile pH Flow Through Cell

PHFLOW-PK5

  • Flow-through cell with integrated optical pH sensor
  • Luer-lock T-Connector with removable pH mini probe
  • Precalibrated for plug & play sterile measurements
  • Sterilized using 25kGy beta-irradiation
  • Luer lock adapters for ca. 3.2 or 4.8 mm ID tubings

Sterile pH Flow Through Cell

PHFLOW-PK6

  • Flow-through cell with integrated optical pH sensor
  • Luer-lock T-Connector with removable pH mini probe
  • Precalibrated for plug & play sterile measurements
  • Sterilized using 25kGy beta-irradiation
  • Luer lock adapters for ca. 3.2 or 4.8 mm ID tubings

Oxygen Sensor Cap for Unterwater Meters

OXCAP-SUB

  • Sensor screw cap with integrated optical oxygen sensor
  • Fast sensor with low drift
  • For all devices with -SUB connector
  • Minimize maintenance by simply exchanging the cap
  • Negligible drift, >3 years shelf time

Ultra-Trace Oxygen Sensor Cap for Underwater Meters

UTROXCAP-SUB

  • Sensor screw cap with integrated optical ultra-trace oxygen sensor
  • Fast sensor with low drift
  • For all devices with -SUB connector
  • Minimized maintenance by simply exchanging the cap

Ultra High-Speed Oxygen Sensor

OXCAPG-UHS-SUB

  • Sensor screw cap with integrated optical oxygen sensor
  • Ultra High speed response time (t90 < 0.5s)
  • Ideal for profiling applications
  • No oxygen consumption

Oxygen Sensor Cap for Profiling

OXCAPG-HS-SUB

  • Sensor screw cap with integrated optical oxygen sensor
  • High speed response time (t90 < 1s)
  • Ideal for profiling applications
  • No oxygen consumption

pH Sensor Cap for Underwater Devices

PHCAP-PK8T-SUB

  • Total Scale pH measurement
  • Robust optical pH sensor caps (4 pcs.) 
  • For all devices with -SUB connector
  • Minimize maintenance by simply exchanging the cap
  • Minimal cross-sensitivity to high ionic strength

pH Sensor Cap for Underwater Devices

PHCAP-PK8-SUB

  • Robust optical pH sensor caps (4 pcs.) 
  • For all devices with -SUB connector
  • Minimize maintenance by simply exchanging the cap
  • Measurement range pH 7.0-9.0
  • Minimal cross-sensitivity to high ionic strength

pH Sensor Cap for Underwater Devices

PHCAP-PK7-SUB

  • Robust optical pH sensor caps (4 pcs.) 
  • For all devices with -SUB connector
  • Minimize maintenance by simply exchanging the cap
  • Measurement range pH 6.0-8.0
  • Minimal cross-sensitivity to high ionic strength

Retractable Fiber Oxygen Minisensor

OXR430

  • Retractable fiber 430µm in diameter
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Temperature Minisensor

TPR430

  • Retractable fiber 430µm in diameter
  • Fast response time (<<1s)
  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXR430
  • Works in gas and in liquids

Robust Screw Cap Temperature Probe

TPROBSC

  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXROBSC
  • With ST-connector 
  • Negligible drift >3 years shelf time

Robust Screw Cap Temperature Probe

TPROBSC-SUB

  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXROBSC-SUB
  • Only for shallow-water applications
  • With underwater SUB-connector (-SUB)

Retractable Fiber Temperature Minisensor

TPR430-SUB

  • Retractable fiber 430µm in diameter
  • Fast response time (<<1s)
  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXR430-SUB
  • With underwater SUB-connector (-SUB)

Protected Tip Oxygen Minisensor

OXF900PT

  • Protected sensor tip by needle
  • Needle diameter 900µm
  • Optimized for measurements in gas
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Fixed Fiber Oxygen Microsensor

OXF50

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption

Bare Fiber Oxygen Microsensor

OXB50

  • 50-70µm sharp sensor tip
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Minisensor

OXB430

  • Optical fiber 430 µm in diameter
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Temperature Minisensor

TPB430-SUB

  • Optical fiber 430µm in diameter
  • Fast response time (<<1s)
  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXB430-SUB
  • With underwater SUB-connector (-SUB)

Bare Fiber Temperature Minisensor

TPB430

  • Optical fiber 430µm in diameter
  • Fast response time (<<1s)
  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXB430
  • Works in gas and in liquids

Robust Oxygen Probe

OXROB3

  • Stainless steel 3cm long, 3mm in diameter
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)
  • Negligible drift, >3 years shelf time

Robust pH Screw Cap Probe

PHROBSC-PK7

  • Measurement range pH 6.0-8.0
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • Precalibrated for plug & play measurements
  • For small amounts of stirred liquid

Robust pH Screw Cap Probe

PHROBSC-PK8

  • Measurement range pH 7.0-9.0
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • Precalibrated for plug & play measurements
  • For small amounts of stirred liquid

Robust pH Screw Cap Probe

PHROBSC-PK5

  • Measurement range pH 4.0-6.0
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • Precalibrated for plug & play measurements
  • For small amounts of stirred liquid

Robust pH Screw Cap Probe

PHROBSC-PK6

  • Measurement range pH 5.0-7.0
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • Precalibrated for plug & play measurements
  • For small amounts of stirred liquid

Robust pH Screw Cap Probe

PHROBSC-PK8T

  • For marine measurements on pH total scale
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • Precalibrated for plug & play measurements
  • For small amounts of stirred liquid

pH Robust Screw Cap Probe

PHROBSC-PK8T-SUB

  • For marine measurements on pH total scale
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • Minimal cross-sensitivity to high ionic strength
  • With underwater SUB-connector (-SUB)
  • For long-term measurements

pH Robust Screw Cap Probe

PHROBSC-PK7-SUB

  • For pH measurements between pH 6.0-8.0
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • Minimal cross-sensitivity to high ionic strength
  • With underwater SUB-connector (-SUB)
  • For long-term measurements

pH Robust Screw Cap Probe

PHROBSC-PK8-SUB

  • For pH measurements between pH 7.0-9.0
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • Minimal cross-sensitivity to high ionic strength
  • With underwater SUB-connector (-SUB)
  • For long-term measurements

Oxygen Sensor Spots for Aquatic Applications

OXSP5-SUB

  • Sensor spots (8 pcs.) 5mm in diameter
  • for underwater devices (-SUB)
  • Minimized influence of hydrostatic pressure
  • Suitable for in-situ incubations
  • No oxygen consumption

Oxygen Respiration Vial

OXVIAL20

  • 20 ml vial with integrated oxygen sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • For small scale respirometry
  • Lids with septum
  • Measures oxygen gas (%oxygen) or dissolved oxygen (DO)

Oxygen Respiration Vial

OXVIAL4

  • 4 ml vial with integrated oxygen sensor
  • Diameter / height: ca. 15 mm / ca. 48 mm
  • For small scale respirometry
  • Lids with septum
  • Measures oxygen gas (%oxygen) or dissolved oxygen (DO)

Fixed Fiber Oxygen Minisensor

OXF1100

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Temperature Sensor Spots

TPSP5

  • Sensor spots (8 pcs.) 5mm in diameter
  • Measurement range 0°C - 50°C
  • For true temperature compensation
  • Works in gas and in liquids
  • Negligible drift >3 years shelf time

Self-Adhesive Temperature Sensor Spots

TPSP5-ADH

  • Self-adhesive sensor spots (8 pcs.) 5mm in diameter
  • For measurements in closed containers
  • Measurement range 0°C - 50°C
  • For true temperature compensation
  • Works in gas and in liquids

Self-Adhesive Sterilized Temperature Sensor Spots

TPSP5-ADH-STER

  • Self-adhesive sensor spots (8 pcs.) 5mm in diameter
  • Sterilized using 25kGy beta-irradiation
  • Measurement range 0°C - 50°C
  • For true temperature compensation
  • Works in gas and in liquids

Trace Range Oxygen Sensor Spots

TROXSP5

  • Sensor spots (8 pcs.) 5mm in diameter
  • For high precision measurements close to 0% O2
  • Works in gas (%oxygen) and in liquids (DO)
  • No oxygen consumption
  • Negligible drift >3 years shelf life

Self-Adhesive Trace Range Oxygen Sensor Spots

TROXSP5-ADH

  • Self-adhesive sensor spots (8 pcs.) 5mm in diameter
  • For measurements in closed containers
  • For high precision measurements close to 0% oxygen
  • Works in gas (%oxygen) and in liquids (DO)
  • No oxygen consumption

Self-Adhesive Sterile Trace Range Oxygen Sensor Spots

TROXSP5-ADH-STER

  • Self-adhesive sensor spots (8 pcs.) 5mm in diameter
  • Sterilized using 25kGy beta-irradiation
  • For high precision measurements close to 0% oxygen
  • No oxygen consumption
  • Works in gas (%oxygen) and in liquids (DO)

Trace Range Robust Oxygen Probe

TROXROB3

  • Stainless steel 3cm long, 3mm in diameter
  • For high precision measurements close to 0% oxygen
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)

Trace Range Robust Oxygen Probe

TROXROB10

  • Stainless steel 10cm long, 3mm in diameter
  • For high precision measurements close to 0% oxygen
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)

Trace Range Fixed Fiber Oxygen Minisensor

TROXF1100

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • For high precision measurements close to 0% oxygen
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption

Trace Range Retractable Fiber Oxygen Minisensor

TROXR430

  • Retractable fiber 430µm in diameter
  • For high precision measurements close to 0% oxygen
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption

Oxygen Monitoring in Organic Solvents

OXSOLV-PTS

  • Works in many polar and nonpolar solvents
  • Protected sensor tip by needle
  • Needle diameter/ length: 1.5mm / 40mm
  • No oxygen consumption

Fixed Fiber Temperature Minisensor

TPF1100

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Fast response time (<<1s)
  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXF1100

Fixed Fiber Temperature Minisensor

TPF1100-SUB

  • Fixed sensor tip surrounded by needle
  • Fast response time (<<1s)
  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXF1100-SUB
  • With underwater SUB-connector (-SUB)

Trace Range Bare Fiber Oxygen Minisensor

TROXB430

  • Optical fiber 430µm in diameter
  • For high precision measurements close to 0% oxygen
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption

Retractable Fiber Oxygen Minisensor

OXR430-HS

  • Retractable fiber 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Minisensor

OXR430-HS-CL4

  • Retractable fiber 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption

Retractable Fiber Oxygen Minisensor

OXR430-UHS-SUB

  • Retractable fiber 430µm in diameter
  • Ultra-high speed response time (t90 < 0.3s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Minisensor

OXR430-UHS

  • Retractable fiber 430µm in diameter
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Minisensor

OXR430-HS-SUB

  • Retractable fiber 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Minisensor

OXR430-CL4

  • Retractable fiber 430µm in diameter
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Minisensor

OXR430-OI

  • Retractable fiber 430µm in diameter
  • Optically isolated (OI)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Minisensor

OXR430-OI-CL4

  • Retractable fiber 430µm in diameter
  • Optically isolated (OI)
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption

Retractable Fiber Oxygen Minisensor

OXR430-OI-SUB

  • Retractable fiber 430µm in diameter
  • Optically isolated (OI)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Minisensor

OXR430-SUB

  • Retractable fiber 430µm in diameter
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Microsensor

OXR50-UHS

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption

Retractable Fiber Oxygen Microsensor

OXR50-HS

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • High speed response time (t90 < 0.8s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption

Retractable Fiber Oxygen Microsensor

OXR50-UHS-CL4

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)

Retractable Fiber Oxygen Microsensor

OXR50-UHS-SUB

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • With underwater SUB-connector (SUB)
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Microsensor

OXR50-HS-SUB

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • High speed response time (t90 < 0.8s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption

Retractable Fiber Oxygen Microsensor

OXR50-CL4

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption

Retractable Fiber Oxygen Microsensor

OXR50-OI-SUB

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption

Retractable Fiber Oxygen Microsensor

OXR50-OI-CL4

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)

Retractable Fiber Oxygen Microsensor

OXR50-SUB

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Microsensor

OXR50-OI

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption

Robust Oxygen Probe

OXROB10-SUB

  • Stainless steel 10cm long, 3mm in diameter
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Optically isolated (OI)
  • Negligible drift, >3 years shelf time

Robust Oxygen Probe

OXROB10-CL4

  • Stainless steel 10cm long, 3mm in diameter
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
  • Optically isolated (OI)
  • Negligible drift, >3 years shelf time

Robust Screw Cap Oxygen Probe

OXROBSC-SUB

  • Robust screw cap probe with 2 oxygen screw cap sensors
  • Stainless steel 10cm long, 4mm in diameter
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)
  • With underwater connector (-SUB)

Robust Oxygen Probe

OXROB3-CL4

  • Stainless steel 3cm long, 3mm in diameter
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
  • Optically isolated (OI)
  • Negligible drift, >3 years shelf time

Robust Oxygen Probe

OXROB3-SUB

  • Stainless steel 3cm long, 3mm in diameter
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Optically isolated (OI)
  • Negligible drift, >3 years shelf time

Trace Range Fixed Fiber Oxygen Minisensor

TROXF1100-CL4

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • For high precision measurements close to 0% oxygen
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)

Fixed Fiber Oxygen Microsensor

OXF50-UHS

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%oxygen) and liquids (DO)

Fixed Fiber Oxygen Microsensor

OXF50-HS

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • High speed response time (t90 < 0.8s)
  • Works in gas (%oxygen) and liquids (DO)

Fixed Fiber Oxygen Microsensor

OXF50-UHS-SUB

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • With underwater SUB-connector (SUB)

Fixed Fiber Oxygen Microsensor

OXF50-HS-SUB

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • High speed response time (t90 < 0.8s)
  • With underwater SUB-connector (SUB)

Fixed Fiber Oxygen Microsensor

OXF50-OI

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • Works in gas (%oxygen) and liquids (DO)

Fixed Fiber Oxygen Microsensor

OXF50-SUB

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • With underwater SUB-connector (SUB)
  • Negligible drift, >3 years shelf time

Fixed Fiber Oxygen Minisensor

OXF1100-UHS

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%oxygen) and liquids (DO)
  • Negligible drift, >3 years shelf time

Fixed Fiber Oxygen Minisensor

OXF1100-UHS-SUB

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Ultra-high speed response time (t90 < 0.3s)
  • With underwater SUB-connector (SUB)
  • Negligible drift, >3 years shelf time

Fixed Fiber Oxygen Minisensor

OXF1100-HS

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • High speed response time (t90 < 0.8s)
  • Works in gas (%oxygen) and liquids (DO)
  • Negligible drift, >3 years shelf time

Fixed Fiber Oxygen Minisensor

OXF1100-HS-SUB

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • High speed response time (t90 < 0.8s)
  • With underwater SUB-connector (SUB)
  • Negligible drift, >3 years shelf time

Fixed Fiber Oxygen Minisensor

OXF1100-CL4

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
  • Negligible drift, >3 years shelf time

Protected Tip Oxygen Minisensor

OXF500PT-OI-CL4

  • Sensor tip protect by needle
  • Needle diameter 500µm
  • Optimized for measurements in gas
  • Optically isolated (OI)
  • 4m cable length (CL4)
 

Fixed Fiber Oxygen Minisensor

OXF1100-OI

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Optically isolated (OI)
  • Works in gas (%oxygen) and liquids (DO)
  • Negligible drift, >3 years shelf time

Fixed Fiber Oxygen Minisensor

OXF1100-OI-CL4

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Optically isolated (OI)
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)

Fixed Fiber Oxygen Minisensor

OXF1100-SUB

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Protected Tip Oxygen Minisensor

OXF500PT-OI

  • Sensor tip protect by needle
  • Needle diameter 500µm
  • Optimized for measurements in gas
  • Optically isolated (OI)
  • No oxygen consumption
 

Protected Tip Oxygen Minisensor

OXF900PT-OI

  • Protected sensor tip by needle
  • Needle diameter 900µm
  • Optimized for measurements in gas
  • Optically isolated (OI)
  • No oxygen consumption

Bare Fiber Oxygen Minisensor

OXB430-UHS

  • Optical fiber 430µm in diameter
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Minisensor

OXB430-HS

  • Optical fiber 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Minisensor

OXB430-HS-SUB

  • Optical fiber 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Minisensor

OXB430-UHS-SUB

  • Optical fiber 430µm in diameter
  • Ultra-high speed response time (t90 < 0.3s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Minisensor

OXB430-UHS-CL4

  • Optical fiber 430µm in diameter
  • Ultra-high speed response time (t90 < 0.3s)
  • 4m cable length (CL4)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-UHS

  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Minisensor

OXB430-SUB

  • Optical fiber 430µm in diameter
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Minisensor

OXB430-OI

  • Optical fiber 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • Optically isolated (OI)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-UHS-SUB

  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-HS

  • 50-70µm sharp sensor tip
  • High speed response time (t90 < 0.8s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-HS-SUB

  • 50-70µm sharp sensor tip
  • High speed response time (t90 < 0.8s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-CL4

  • 50-70µm sharp sensor tip
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-OI

  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-SUB

  • Optical fiber 230µm in diameter
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-OI-CL4

  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • 4m cable length (CL4)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Pt100 Temperature Probe

TDIP15

  • Stainless steel temperature dipping probe
  • Robust tip and shielded cable
  • With LEMO-connector
  • Only tip submersible in water
  • Fast response time (2s/1min in water/air)

Pt100 Temperature Probe

TSUB21

  • Flexible Teflon-coated temperature probe
  • With LEMO-connector
  • Tip and cable are completely submersible in water
  • Response time ca. 8s/1min in water/air

Pt100 Temperature Probe

TSUB21-NC

  • Flexible Teflon-coated temperature probe
  • With no connector (-NC) for Pt100 soldering
  • Tip and cable are completely submersible in water
  • Response time ca. 8s/1min in water/air

Pt100 Temperature Probe

TSUB21-CL1

  • Flexible Teflon-coated temperature probe
  • Shorter 1m cable length (CL1)
  • Tip stable in approved solvents (with OXSOLV sensor)
  • With LEMO-connector

Pt100 Temperature Probe

TSUB21-CL20

  • Flexible Teflon-coated temperature probe
  • Extended 20m cable length (CL20)
  • For oxygen sensors with cable length >5m
  • With LEMO-connector
  • Tip and cable are completely submersible in water

Pt100 Temperature Probe

TSUB21-CL5

  • Flexible Teflon-coated temperature probe
  • Extended 5m cable length (CL5)
  • For oxygen sensors with cable length of 4m (-CL4)
  • With LEMO-connector
  • Tip and cable are completely submersible in water

Would you like to stay informed?