search

PyroScience Sensors

Filter Optionsi

Robust Oxygen Probe

OXROB10

  • Stainless steel 10cm long, 3mm in diameter
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)
  • Negligible drift, >3 years shelf time

Robust Screw Cap Oxygen Probe

OXROBSC

  • Robust screw cap probe with 2 oxygen screw cap sensors
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)

Retractable Fiber Oxygen Microsensor

OXR50

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Robust Screw Cap Oxygen Probe

OXROBGSC-CL5

  • Robust screw cap probe with 2 oxygen screw cap sensors
  • 5m cable length (-CL5)
  • Works in gas (%O2) and liquids (DO)
  • Optically isolated (-OI)

Protected Tip Oxygen Minisensor

OXF500PT

  • Sensor tip protect by needle
  • Needle diameter 500µm
  • Optimized for measurements in gas
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Oxygen Sensor Spots

OXSP5

  • For measurements in closed containers
  • Autoclavable (few times, short cycle)
  • Works in gas (%O2) and in liquids (DO)
  • No oxygen consumption
  • Negligible drift >3 years shelf time

Self-Adhesive Oxygen Sensor Spots

OXSP5-ADH

  • Self-adhesive sensor spots for easy integration
  • For measurements in closed containers
  • Works in gas (%O2) and in liquids (DO)
  • No oxygen consumption
  • Negligible drift >3 years shelf time

pH Sensor Spots

PHSP5-PK7

  • Measurement range pH 6.0-8.0
  • For measurements in closed containers
  • No reference electrode required
  • Contamination-free non-invasive measurement

Self-Adhesive pH Sensor Spots

PHSP5-PK7-ADH

  • Self-adhesive sensor spots for easy integration
  • Measurement range pH 6.0-8.0
  • For measurements in closed containers
  • No reference electrode required
  • Contamination-free non-invasive measurement

pH Sensor Spots

PHSP5-PK8

  • Measurement range pH 7.0-9.0
  • For measurements in closed containers
  • No reference electrode required
  • Contamination-free due to non-invasive measurement

Self-Adhesive pH Sensor Spots

PHSP5-PK8-ADH

  • Self-adhesive sensor spots for easy integration
  • Measurement range pH 7.0-9.0
  • For measurements in closed containers
  • No reference electrode required
  • Contamination-free non-invasive measurement

pH Sensor Spots

PHSP5-PK5

  • Measurement range pH 4.0-6.0
  • For measurements in closed containers
  • No reference electrode required
  • Contamination-free due to non-invasive measurement

pH Sensor Spots

PHSP5-PK6

  • Measurement range pH 5.0-7.0
  • For measurements in closed containers
  • No reference electrode required
  • Contamination-free due to non-invasive measurement

pH Sensor Spots

PHSP5-PK8T

  • For marine measurements on pH total scale
  • Measurement range pH 7.0-9.0
  • For measurements in closed containers
  • No reference electrode required
  • Contamination-free due to non-invasive measurement

Self-Adhesive pH Sensor Spots

PHSP5-PK5-ADH

  • Self-adhesive sensor spots for easy integration
  • Measurement range pH 4.0-6.0
  • For measurements in closed containers
  • No reference electrode required
  • Contamination-free non-invasive measurement

Self-Adhesive pH Sensor Spots

PHSP5-PK6-ADH

  • Self-adhesive sensor spots for easy integration
  • Measurement range pH 5.0-7.0
  • No reference electrode required
  • Contamination-free non-invasive measurement

Self-Adhesive pH Sensor Spots

PHSP5-PK8T-ADH

  • Self-adhesive sensor spots for easy integration
  • For marine measurements on pH total scale
  • Measurement range pH 7.0-9.0
  • No reference electrode required
  • Contamination-free non-invasive measurement

Oxygen Nanoprobes

OXNANO

  • Dispersible oxygen nanoparticles
  • Ideal for microfluidics or lab-on-a-chip
  • For measurement in complex geometries
  • Autoclavable (few times, short cycle)
  • Real-time response

Oxygen Monitoring in Organic Solvents

OXSOLV

  • Works in many polar and nonpolar solvents
  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Needle diameter/ length: 1.5mm / 150mm
  • No oxygen consumption

Robust Screw Cap Oxygen Probe

OXROBGSC-CL10

  • Robust screw cap probe with 2 oxygen screw cap sensors
  • 10m cable length (-CL10)
  • Works in gas (%O2) and liquids (DO)
  • Optically isolated (-OI)

Robust Screw Cap Oxygen Probe

OXROBGSC-CL20

  • Robust screw cap probe with 2 oxygen screw cap sensors
  • 20m cable length (-CL20)
  • Works in gas (%O2) and liquids (DO)
  • Optically isolated (-OI)

Oxygen & Temperature Flow-Through Cell

TOFTC2

  • With contactless oxygen & temp sensor
  • For ca. 3.2 or 4.0 mm ID tubings
  • Recommended flow rate: 20-500 mL/min
  • Measurement range temp 0°C - 50°C
  • True temperature compensation possible

Oxygen Flow-Through Cell

OXFTC

  • With integrated contactless optical oxygen sensor
  • Luer-lock with tubing adapters
  • For ca. 1.6 or 2.4 mm ID tubings
  • Recommended flow rate: 10-100 mL/min
  • Works with gas (%O2) and liquids (DO)

Oxygen & Temperature Respiration Vial

TOVIAL20

  • 20 ml vial with integrated oxygen & temp sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measures oxygen gas (%O2) or dissolved oxygen (DO)
  • Measurement range temp 0°C - 50°C
  • True temperature compensation possible

Oxygen & pH & Temperature Vial

PHTOVIAL20-PK7

  • 20 ml vial with integrated pH + temp + oxygen sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measurement range pH 6.0-8.0
  • Measurement range temp 0°C - 50°C
  • True temperature compensation

Oxygen & pH & Temperature Vial

PHTOVIAL20-PK8

  • 20 ml vial with integrated pH + temp + oxygen sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measurement range pH 7.0-9.0
  • Measurement range temp 0°C - 50°C
  • True temperature compensation

pH Flow-Through Cell

PHFTCR-PK7

  • Measurement range pH 6.0-8.0
  • Luer-lock T-Connector with removable pH mini probe
  • For ca. 3.2 or 4.8 mm ID tubings
  • No reference electrode required

pH Flow-Through Cell

PHFTCR-PK8

  • Measurement range pH 7.0-9.0
  • Luer-lock T-Connector with removable pH mini probe
  • For ca. 3.2 or 4.8 mm ID tubings
  • No reference electrode required

pH Flow-Through Cell

PHFTCR-PK6

  • Measurement range pH 5.0-4.0
  • Luer-lock T-Connector with removable pH mini probe
  • For ca. 3.2 or 4.8 mm ID tubings
  • No reference electrode required

pH Flow-Through Cell

PHFTCR-PK8T

  • For marine measurements on pH total scale
  • Luer-lock T-Connector with removable pH mini probe
  • For ca. 3.2 or 4.8 mm ID tubings
  • No reference electrode required

pH Flow-Through Cell

PHFTCR-PK5

  • Measurement range pH 4.0-6.0
  • Luer-lock T-Connector with removable pH mini probe
  • For ca. 3.2 or 4.8 mm ID tubings
  • No reference electrode required

Oxygen Sensor Cap for Unterwater Meters

OXCAP-SUB

  • Sensor screw cap with integrated optical oxygen sensor
  • Fast sensor with low drift
  • For all devices with -SUB connector
  • Minimize maintenance by simply exchanging the cap
  • Negligible drift, >3 years shelf time

Ultra High-Speed Oxygen Sensor

OXCAPG-UHS-SUB

  • Sensor screw cap with integrated optical oxygen sensor
  • Ultra High speed response time (t90 < 0.5s)
  • Ideal for profiling applications
  • No oxygen consumption

Oxygen Sensor Cap for Profiling

OXCAPG-HS-SUB

  • Sensor screw cap with integrated optical oxygen sensor
  • High speed response time (t90 < 1s)
  • Ideal for profiling applications
  • No oxygen consumption

pH Sensor Cap for Underwater Devices

PHCAP-PK8T-SUB

  • Total Scale pH measurement
  • Robust sensor cap with integrated optical pH sensor
  • For all devices with -SUB connector
  • Minimize maintenance by simply exchanging the cap
  • Minimal cross-sensitivity to high ionic strength

pH Sensor Cap for Underwater Devices

PHCAP-PK8-SUB

  • Robust sensor cap with integrated optical pH sensor
  • For all devices with -SUB connector
  • Minimize maintenance by simply exchanging the cap
  • Measurement range pH 7.0-9.0
  • Minimal cross-sensitivity to high ionic strength

pH Sensor Cap for Underwater Devices

PHCAP-PK7-SUB

  • Robust sensor cap with integrated optical pH sensor
  • For all devices with -SUB connector
  • Minimize maintenance by simply exchanging the cap
  • Measurement range pH 6.0-8.0
  • Minimal cross-sensitivity to high ionic strength

Oxygen Flow-Through Cell

OXFTCR

  • Luer-lock T-Connector with removable robust oxygen probe
  • For ca. 3.2 or 4.8 mm ID tubings
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption

Retractable Fiber Oxygen Minisensor

OXR430

  • Retractable fiber 430µm in diameter
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Temperature Minisensor

TPR430

  • Retractable fiber 430µm in diameter
  • Fast response time (<<1s)
  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXR430
  • Works in gas and in liquids

Robust Screw Cap Temperature Probe

TPROBSC

  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXROBSC
  • With underwater ST-connector 
  • Negligible drift >3 years shelf time

Robust Screw Cap Temperature Probe

TPROBSC-SUB

  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXROBSC-SUB
  • With underwater SUB-connector (-SUB)
  • Negligible drift >3 years shelf time

Retractable Fiber Temperature Minisensor

TPR430-SUB

  • Retractable fiber 430µm in diameter
  • Fast response time (<<1s)
  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXR430-SUB
  • With underwater SUB-connector (-SUB)

Protected Tip Oxygen Minisensor

OXF900PT

  • Protected sensor tip by needle
  • Needle diameter 900µm
  • Optimized for measurements in gas
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Fixed Fiber Oxygen Microsensor

OXF50

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption

Bare Fiber Oxygen Microsensor

OXB50

  • 50-70µm sharp sensor tip
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Minisensor

OXB430

  • Optical fiber 430 µm in diameter
  • Works in gas (% O2) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Temperature Minisensor

TPB430-SUB

  • Optical fiber 430µm in diameter
  • Fast response time (<<1s)
  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXB430-SUB
  • With underwater SUB-connector (-SUB)

Bare Fiber Temperature Minisensor

TPB430

  • Optical fiber 430µm in diameter
  • Fast response time (<<1s)
  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXB430
  • Works in gas and in liquids

Robust Oxygen Probe

OXROB3

  • Stainless steel 3cm long, 3mm in diameter
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)
  • Negligible drift, >3 years shelf time

Robust pH Screw Cap Probe

PHROBSC-PK7

  • Measurement range pH 6.0-8.0
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • No reference electrode required
  • For small amounts of stirred liquid

Robust pH Screw Cap Probe

PHROBSC-PK8

  • Measurement range pH 7.0-9.0
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • No reference electrode required
  • For small amounts of stirred liquid

Robust pH Screw Cap Probe

PHROBSC-PK5

  • Measurement range pH 4.0-6.0
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • No reference electrode required
  • For small amounts of stirred liquid

Robust pH Screw Cap Probe

PHROBSC-PK6

  • Measurement range pH 5.0-7.0
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • No reference electrode required
  • For small amounts of stirred liquid

Robust pH Screw Cap Probe

PHROBSC-PK8T

  • For marine measurements on pH total scale
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • No reference electrode required
  • For small amounts of stirred liquid

pH Robust Screw Cap Probe

PHROBSC-PK8T-SUB

  • For marine measurements on pH total scale
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • Minimal cross-sensitivity to high ionic strength
  • With underwater SUB-connector (-SUB)
  • For long-term measurements

pH Robust Screw Cap Probe

PHROBSC-PK7-SUB

  • For pH measurements between pH 6.0-8.0
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • Minimal cross-sensitivity to high ionic strength
  • With underwater SUB-connector (-SUB)
  • For long-term measurements

pH Robust Screw Cap Probe

PHROBSC-PK8-SUB

  • For pH measurements between pH 7.0-9.0
  • Robust fiber with threaded tip
  • Exchangeable Sensor Screw Caps
  • Minimal cross-sensitivity to high ionic strength
  • With underwater SUB-connector (-SUB)
  • For long-term measurements

pH & Temperature Vial

PHTVIAL20-PK7

  • 20 ml vial with integrated pH + temp sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measurement range pH 6.0-8.0
  • Measurement range temp 0°C - 50°C
  • True temperature compensation

pH & Temperature Vial

PHTVIAL20-PK8

  • 20 ml vial with integrated pH + temp sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measurement range pH 7.0-9.0
  • Measurement range temp 0°C - 50°C
  • True temperature compensation

pH Vial

PHVIAL20-PK7

  • 20 ml vial with integrated pH sensor stripe
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measurement range pH 6.0-8.0

pH Vial

PHVIAL20-PK8

  • 20 ml vial with integrated pH sensor stripe
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measurement range pH 7.0-9.0

Oxygen Sensor Spots for Aquatic Applications

OXSP5-SUB

  • Minimized influence of hydrostatic pressure
  • For measurements in closed containers
  • Suitable for in-situ incubations
  • No oxygen consumption

Oxygen Respiration Vial

OXVIAL20

  • 20 ml vial with integrated oxygen sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • For small scale respirometry
  • Lids with septum
  • Measures oxygen gas (%O2) or dissolved oxygen (DO)

Oxygen Respiration Vial

OXVIAL4

  • 4 ml vial with integrated oxygen sensor
  • Diameter / height: ca. 15 mm / ca. 48 mm
  • For small scale respirometry
  • Lids with septum
  • Measures oxygen gas (%O2) or dissolved oxygen (DO)

Fixed Fiber Oxygen Minisensor

OXF1100

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Oxygen Flow-Through Cell

OXFTC2

  • With contactless optical oxygen sensor
  • Luer-lock with tubing adapters
  • For ca. 3.2 or 4.0 mm ID tubings
  • Recommended flow rate: 20-500 mL/min
  • Works with gas (%O2) and liquids (DO)

Temperature Flow-Through Cell

TPFTC2

  • With contactless optical temperature sensor
  • Luer-lock with tubing adapters
  • For ca. 3.2 or 4.0 mm ID tubings
  • Recommended flow rate: 20-500 mL/min
  • Measurement range 0°C - 50°C

Temperature Sensor Spots

TPSP5

  • For measurements in closed containers
  • Measurement range 0°C - 50°C
  • For true temperature compensation
  • Works in gas and in liquids
  • Negligible drift >3 years shelf time

Self-Adhesive Temperature Sensor Spots

TPSP5-ADH

  • Self-adhesive sensor spots for easy integration
  • For measurements in closed containers
  • Measurement range 0°C - 50°C
  • For true temperature compensation
  • Works in gas and in liquids

Trace Range Oxygen Sensor Spots

TROXSP5

  • For measurements in closed containers
  • For high precision measurements close to 0% O2
  • Works in gas (%O2) and in liquids (DO)
  • No oxygen consumption
  • Negligible drift >3 years shelf time

Self-Adhesive Trace Range Oxygen Sensor Spots

TROXSP5-ADH

  • Self-adhesive sensor spots for easy integration
  • For measurements in closed containers
  • For high precision measurements close to 0% O2
  • Works in gas (%O2) and in liquids (DO)
  • No oxygen consumption

Trace Range Robust Oxygen Probe

TROXROB3

  • Stainless steel 3cm long, 3mm in diameter
  • For high precision measurements close to 0% O2
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)

Trace Range Robust Oxygen Probe

TROXROB10

  • Stainless steel 10cm long, 3mm in diameter
  • For high precision measurements close to 0% O2
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)

Trace Range Fixed Fiber Oxygen Minisensor

TROXF1100

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • For high precision measurements close to 0% O2
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption

Trace Range Retractable Fiber Oxygen Minisensor

TROXR430

  • Retractable fiber 430µm in diameter
  • For high precision measurements close to 0% O2
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption

Trace Range Oxygen Flow-Through Cell

TROXFTC

  • With integrated contactless optical oxygen sensor
  • For high precision measurements close to 0% O2
  • For ca. 1.6 or 2.4 mm ID tubings
  • Recommended flow rate: 10-100 mL/min
  • Works with gas (%O2) and liquids (DO)

Oxygen Monitoring in Organic Solvents

OXSOLV-PTS

  • Works in many polar and nonpolar solvents
  • Protected sensor tip by needle
  • Needle diameter/ length: 1.5mm / 40mm
  • No oxygen consumption

Trace Range Oxygen Flow-Through Cell

TROXFTC2

  • With contactless optical oxygen sensor
  • For high precision measurements close to 0% O2
  • For ca. 3.2 or 4.0 mm ID tubings
  • Recommended flow rate: 20-500 mL/min
  • Works with gas (%O2) and liquids (DO)

Robust Oxygen Dipping Probe

OPDIP20

  • Stainless steel 20cm long, 3mm in diameter
  • PICO-connector
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)

Robust Oxygen Probe

OPROB3

  • Stainless steel 3cm long, 3mm in diameter
  • 1m fiber length, PICO-connector
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)

Fixed Fiber Temperature Minisensor

TPF1100

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Fast response time (<<1s)
  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXF1100

Fixed Fiber Temperature Minisensor

TPF1100-SUB

  • Fixed sensor tip surrounded by needle
  • Fast response time (<<1s)
  • Measurement range 0°C - 50°C
  • For true temperature compensation of OXF1100-SUB
  • With underwater SUB-connector (-SUB)

Trace Range Bare Fiber Oxygen Minisensor

TROXB430

  • Optical fiber 430µm in diameter
  • For high precision measurements close to 0% O2
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption

Retractable Fiber Oxygen Minisensor

OXR430-HS

  • Retractable fiber 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Minisensor

OXR430-HS-CL4

  • Retractable fiber 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • 4m cable length (CL4)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption

Retractable Fiber Oxygen Minisensor

OXR430-UHS-SUB

  • Retractable fiber 430µm in diameter
  • Ultra-high speed response time (t90 < 0.3s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Minisensor

OXR430-UHS

  • Retractable fiber 430µm in diameter
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Minisensor

OXR430-HS-SUB

  • Retractable fiber 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Minisensor

OXR430-CL4

  • Retractable fiber 430µm in diameter
  • 4m cable length (CL4)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Minisensor

OXR430-OI

  • Retractable fiber 430µm in diameter
  • Optically isolated (OI)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Minisensor

OXR430-OI-CL4

  • Retractable fiber 430µm in diameter
  • Optically isolated (OI)
  • 4m cable length (CL4)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption

Retractable Fiber Oxygen Minisensor

OXR430-OI-SUB

  • Retractable fiber 430µm in diameter
  • Optically isolated (OI)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Minisensor

OXR430-SUB

  • Retractable fiber 430µm in diameter
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Microsensor

OXR50-UHS

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption

Retractable Fiber Oxygen Microsensor

OXR50-HS

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • High speed response time (t90 < 0.8s)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption

Retractable Fiber Oxygen Microsensor

OXR50-UHS-CL4

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • 4m cable length (CL4)
  • Works in gas (%O2) and liquids (DO)

Retractable Fiber Oxygen Microsensor

OXR50-UHS-SUB

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • With underwater SUB-connector (SUB)
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Microsensor

OXR50-HS-SUB

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • High speed response time (t90 < 0.8s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption

Retractable Fiber Oxygen Microsensor

OXR50-CL4

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • 4m cable length (CL4)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption

Retractable Fiber Oxygen Microsensor

OXR50-OI-SUB

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption

Retractable Fiber Oxygen Microsensor

OXR50-OI-CL4

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • 4m cable length (CL4)
  • Works in gas (%O2) and liquids (DO)

Retractable Fiber Oxygen Microsensor

OXR50-SUB

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Retractable Fiber Oxygen Microsensor

OXR50-OI

  • Retractable fiber 230µm in diameter
  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption

Robust Oxygen Probe

OXROB10-CL4

  • Stainless steel 10cm long, 3mm in diameter
  • 4m cable length (CL4)
  • Works in gas (%O2) and liquids (DO)
  • Optically isolated (OI)
  • Negligible drift, >3 years shelf time

Robust Screw Cap Oxygen Probe

OXROBSC-SUB

  • Robust screw cap probe with 2 oxygen screw cap sensors
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Optically isolated (OI)
  • With underwater connector (-SUB)

Robust Oxygen Probe

OXROB10-CL4-SUB

  • Stainless steel 10cm long, 3mm in diameter
  • 4m cable length (CL4)
  • With underwater SUB-connector (SUB)
  • Optically isolated (OI)
  • Negligible drift, >3 years shelf time

Robust Oxygen Probe

OXROB3-CL4

  • Stainless steel 3cm long, 3mm in diameter
  • 4m cable length (CL4)
  • Works in gas (%O2) and liquids (DO)
  • Optically isolated (OI)
  • Negligible drift, >3 years shelf time

Robust Oxygen Probe

OXROB3-SUB

  • Stainless steel 3cm long, 3mm in diameter
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Optically isolated (OI)
  • Negligible drift, >3 years shelf time

Robust Oxygen Probe

OXROB3-CL4-SUB

  • Stainless steel 3cm long, 3mm in diameter
  • With underwater SUB-connector (SUB)
  • 4m cable length (CL4)
  • Optically isolated (OI)
  • Negligible drift, >3 years shelf time

Trace Range Fixed Fiber Oxygen Minisensor

TROXF1100-CL4

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • For high precision measurements close to 0% O2
  • 4m cable length (CL4)
  • Works in gas (%O2) and liquids (DO)

Fixed Fiber Oxygen Microsensor

OXF50-UHS

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%O2) and liquids (DO)

Fixed Fiber Oxygen Microsensor

OXF50-HS

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • High speed response time (t90 < 0.8s)
  • Works in gas (%O2) and liquids (DO)

Fixed Fiber Oxygen Microsensor

OXF50-UHS-SUB

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • With underwater SUB-connector (SUB)

Fixed Fiber Oxygen Microsensor

OXF50-HS-SUB

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • High speed response time (t90 < 0.8s)
  • With underwater SUB-connector (SUB)

Fixed Fiber Oxygen Microsensor

OXF50-OI

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • Works in gas (%O2) and liquids (DO)

Fixed Fiber Oxygen Microsensor

OXF50-SUB

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • With underwater SUB-connector (SUB)
  • Negligible drift, >3 years shelf time

Fixed Fiber Oxygen Minisensor

OXF1100-UHS

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%O2) and liquids (DO)
  • Negligible drift, >3 years shelf time

Fixed Fiber Oxygen Minisensor

OXF1100-UHS-SUB

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Ultra-high speed response time (t90 < 0.3s)
  • With underwater SUB-connector (SUB)
  • Negligible drift, >3 years shelf time

Fixed Fiber Oxygen Minisensor

OXF1100-HS

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • High speed response time (t90 < 0.8s)
  • Works in gas (%O2) and liquids (DO)
  • Negligible drift, >3 years shelf time

Fixed Fiber Oxygen Minisensor

OXF1100-HS-SUB

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • High speed response time (t90 < 0.8s)
  • With underwater SUB-connector (SUB)
  • Negligible drift, >3 years shelf time

Fixed Fiber Oxygen Minisensor

OXF1100-CL4

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • 4m cable length (CL4)
  • Works in gas (%O2) and liquids (DO)
  • Negligible drift, >3 years shelf time

Protected Tip Oxygen Minisensor

OXF500PT-OI-CL4

  • Sensor tip protect by needle
  • Needle diameter 500µm
  • Optimized for measurements in gas
  • Optically isolated (OI)
  • 4m cable length (CL4)
 

Fixed Fiber Oxygen Minisensor

OXF1100-OI

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Optically isolated (OI)
  • Works in gas (%O2) and liquids (DO)
  • Negligible drift, >3 years shelf time

Fixed Fiber Oxygen Minisensor

OXF1100-OI-CL4

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Optically isolated (OI)
  • 4m cable length (CL4)
  • Works in gas (%O2) and liquids (DO)

Fixed Fiber Oxygen Minisensor

OXF1100-SUB

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Protected Tip Oxygen Minisensor

OXF500PT-OI

  • Sensor tip protect by needle
  • Needle diameter 500µm
  • Optimized for measurements in gas
  • Optically isolated (OI)
  • No oxygen consumption
 

Protected Tip Oxygen Minisensor

OXF900PT-OI

  • Protected sensor tip by needle
  • Needle diameter 900µm
  • Optimized for measurements in gas
  • Optically isolated (OI)
  • No oxygen consumption

Bare Fiber Oxygen Minisensor

OXB430-UHS

  • Optical fiber 430µm in diameter
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Minisensor

OXB430-HS

  • Optical fiber 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Minisensor

OXB430-HS-SUB

  • Optical fiber 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Minisensor

OXB430-UHS-SUB

  • Optical fiber 430µm in diameter
  • Ultra-high speed response time (t90 < 0.3s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Minisensor

OXB430-UHS-CL4

  • Optical fiber 430µm in diameter
  • Ultra-high speed response time (t90 < 0.3s)
  • 4m cable length (CL4)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-UHS

  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Minisensor

OXB430-SUB

  • Optical fiber 430µm in diameter
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Minisensor

OXB430-OI

  • Optical fiber 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • Optically isolated (OI)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-UHS-SUB

  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-HS

  • 50-70µm sharp sensor tip
  • High speed response time (t90 < 0.8s)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-HS-SUB

  • 50-70µm sharp sensor tip
  • High speed response time (t90 < 0.8s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-CL4

  • 50-70µm sharp sensor tip
  • 4m cable length (CL4)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-OI

  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • Works in gas (%O2) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-SUB

  • 50-70µm sharp sensor tip
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Bare Fiber Oxygen Microsensor

OXB50-OI-CL4

  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • 4m cable length (CL4)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Pt100 Temperature Probe

TDIP15

  • Stainless steel temperature dipping probe
  • Robust tip and shielded cable
  • With LEMO-connector
  • Only tip submersible in water
  • Fast response time (2s/1min in water/air)

Pt100 Temperature Probe

TSUB21

  • Flexible Teflon-coated temperature probe
  • With LEMO-connector
  • Tip and cable are completely submersible in water
  • Response time ca. 8s/1min in water/air

Pt100 Temperature Probe

TSUB21-NC

  • Flexible Teflon-coated temperature probe
  • With no connector (-NC) for Pt100 soldering
  • Tip and cable are completely submersible in water
  • Response time ca. 8s/1min in water/air

Pt100 Temperature Probe

TSUB21-CL1

  • Flexible Teflon-coated temperature probe
  • Shorter 1m cable length (CL1)
  • Tip stable in approved solvents (with OXSOLV sensor)
  • With LEMO-connector

Pt100 Temperature Probe

TSUB21-CL5

  • Flexible Teflon-coated temperature probe
  • Extended 5m cable length (CL5)
  • For oxygen sensors with cable length of 4m (-CL4)
  • With LEMO-connector
  • Tip and cable are completely submersible in water