Oxygen Sensor Spots

OXSP5

  • For measurements in closed containers
  • Autoclavable (few times, short cycle)
  • Works in gas (%O2) and in liquids (DO)
  • No oxygen consumption
  • Negligible drift >3 years shelf time

pH Sensor Spots

PHSP5-PK7

  • Measurement range pH 6.0-8.0
  • For measurements in closed containers
  • No reference electrode required
  • Contamination-free due to non-invasive measurement

pH Sensor Spots

PHSP5-PK8

  • Measurement range pH 7.0-9.0
  • For measurements in closed containers
  • No reference electrode required
  • Contamination-free due to non-invasive measurement

pH Sensor Spots

PHSP5-PK5

  • Measurement range pH 4.0-6.0
  • For measurements in closed containers
  • No reference electrode required
  • Contamination-free due to non-invasive measurement

pH Sensor Spots

PHSP5-PK6

  • Measurement range pH 5.0-7.0
  • For measurements in closed containers
  • No reference electrode required
  • Contamination-free due to non-invasive measurement

pH Sensor Spots

PHSP5-PK8T

  • For marine measurements on pH total scale
  • Measurement range pH 7.0-9.0
  • For measurements in closed containers
  • No reference electrode required
  • Contamination-free due to non-invasive measurement

Oxygen Nanoprobes

OXNANO

  • Dispersible oxygen nanoparticles
  • Ideal for microfluidics or lab-on-a-chip
  • For measurement in complex geometries
  • Autoclavable (few times, short cycle)
  • Real-time response

Oxygen & Temperature Flow-Through Cell

TOFTC2

  • With contactless oxygen & temp sensor
  • For ca. 3.2 or 4.0 mm ID tubings
  • Recommended flow rate: 20-500 mL/min
  • Measurement range temp 0°C - 50°C
  • True temperature compensation possible

Oxygen Flow-Through Cell

OXFTC

  • With integrated contactless optical oxygen sensor
  • Luer-lock with tubing adapters
  • For ca. 1.6 or 2.4 mm ID tubings
  • Recommended flow rate: 10-100 mL/min
  • Works with gas (%O2) and liquids (DO)

Oxygen & Temperature Respiration Vial

TOVIAL20

  • 20 ml vial with integrated oxygen & temp sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measures oxygen gas (%O2) or dissolved oxygen (DO)
  • Measurement range temp 0°C - 50°C
  • True temperature compensation possible

Oxygen & pH & Temperature Vial

PHTOVIAL20-PK7

  • 20 ml vial with integrated pH + temp + oxygen sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measurement range pH 6.0-8.0
  • Measurement range temp 0°C - 50°C
  • True temperature compensation

Oxygen & pH & Temperature Vial

PHTOVIAL20-PK8

  • 20 ml vial with integrated pH + temp + oxygen sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measurement range pH 7.0-9.0
  • Measurement range temp 0°C - 50°C
  • True temperature compensation

pH Flow-Through Cell

PHFTCR-PK7

  • Measurement range pH 6.0-8.0
  • Luer-lock T-Connector with removable pH mini probe
  • For ca. 3.2 or 4.8 mm ID tubings
  • No reference electrode required

pH Flow-Through Cell

PHFTCR-PK8

  • Measurement range pH 7.0-9.0
  • Luer-lock T-Connector with removable pH mini probe
  • For ca. 3.2 or 4.8 mm ID tubings
  • No reference electrode required

pH Flow-Through Cell

PHFTCR-PK5

  • Measurement range pH 4.0-6.0
  • Luer-lock T-Connector with removable pH mini probe
  • For ca. 3.2 or 4.8 mm ID tubings
  • No reference electrode required

pH Flow-Through Cell

PHFTCR-PK6

  • Measurement range pH 5.0-4.0
  • Luer-lock T-Connector with removable pH mini probe
  • For ca. 3.2 or 4.8 mm ID tubings
  • No reference electrode required

pH Flow-Through Cell

PHFTCR-PK8T

  • For marine measurements on pH total scale
  • Luer-lock T-Connector with removable pH mini probe
  • For ca. 3.2 or 4.8 mm ID tubings
  • No reference electrode required

pH & Temperature Vial

PHTVIAL20-PK7

  • 20 ml vial with integrated pH + temp sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measurement range pH 6.0-8.0
  • Measurement range temp 0°C - 50°C
  • True temperature compensation

pH & Temperature Vial

PHTVIAL20-PK8

  • 20 ml vial with integrated pH + temp sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measurement range pH 7.0-9.0
  • Measurement range temp 0°C - 50°C
  • True temperature compensation

pH Vial

PHVIAL20-PK7

  • 20 ml vial with integrated pH sensor stripe
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measurement range pH 6.0-8.0

pH Vial

PHVIAL20-PK8

  • 20 ml vial with integrated pH sensor stripe
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • Measurement range pH 7.0-9.0

Oxygen Respiration Vial

OXVIAL20

  • 20 ml vial with integrated oxygen sensor
  • Diameter / height: ca. 28 mm / ca. 61 mm
  • For small scale respirometry
  • Lids with septum
  • Measures oxygen gas (%O2) or dissolved oxygen (DO)

Oxygen Respiration Vial

OXVIAL4

  • 4 ml vial with integrated oxygen sensor
  • Diameter / height: ca. 15 mm / ca. 48 mm
  • For small scale respirometry
  • Lids with septum
  • Measures oxygen gas (%O2) or dissolved oxygen (DO)

Oxygen Flow-Through Cell

OXFTC2

  • With contactless optical oxygen sensor
  • Luer-lock with tubing adapters
  • For ca. 3.2 or 4.0 mm ID tubings
  • Recommended flow rate: 20-500 mL/min
  • Works with gas (%O2) and liquids (DO)

Temperature Flow-Through Cell

TPFTC2

  • With contactless optical temperature sensor
  • Luer-lock with tubing adapters
  • For ca. 3.2 or 4.0 mm ID tubings
  • Recommended flow rate: 20-500 mL/min
  • Measurement range 0°C - 50°C

Temperature Sensor Spots

TPSP5

  • For measurements in closed containers
  • Measurement range 0°C - 50°C
  • For true temperature compensation
  • Works in gas and in liquids
  • Negligible drift >3 years shelf time

Trace Range Oxygen Sensor Spots

TROXSP5

  • For measurements in closed containers
  • For high precision measurements close to 0% O2
  • Works in gas (%O2) and in liquids (DO)
  • No oxygen consumption
  • Negligible drift >3 years shelf time

Trace Range Oxygen Flow-Through Cell

TROXFTC

  • With integrated contactless optical oxygen sensor
  • For high precision measurements close to 0% O2
  • For ca. 1.6 or 2.4 mm ID tubings
  • Recommended flow rate: 10-100 mL/min
  • Works with gas (%O2) and liquids (DO)

Trace Range Oxygen Flow-Through Cell

TROXFTC2

  • With contactless optical oxygen sensor
  • For high precision measurements close to 0% O2
  • For ca. 3.2 or 4.0 mm ID tubings
  • Recommended flow rate: 20-500 mL/min
  • Works with gas (%O2) and liquids (DO)

Oxygen Sensor Spots for Aquatic Applications

OXSP5-SUB

  • Minimized influence of hydrostatic pressure
  • For measurements in closed containers
  • Suitable for in-situ incubations
  • No oxygen consumption