Robust Oxygen Probe
OXROB10
- Stainless steel 10cm long, 3mm in diameter
- Works in gas (%O2) and liquids (DO)
- No oxygen consumption
- Optically isolated (OI)
- Negligible drift, >3 years shelf time
Fixed Fiber Oxygen Microsensor
OXF50
- Fixed sensor tip surrounded by needle
- Sensor tip protrudes ca. 6mm
- 50-70µm sharp sensor tip
- Works in gas (%O2) and liquids (DO)
- No oxygen consumption
Robust Oxygen Probe
OXROB3
- Stainless steel 3cm long, 3mm in diameter
- Works in gas (%O2) and liquids (DO)
- No oxygen consumption
- Optically isolated (OI)
- Negligible drift, >3 years shelf time
Fixed Fiber Oxygen Minisensor
OXF1100
- Fixed sensor tip surrounded by needle
- Sensor tip protrudes ca. 2mm
- Works in gas (%O2) and liquids (DO)
- No oxygen consumption
- Negligible drift, >3 years shelf time
Trace Range Robust Oxygen Probe
TROXROB3
- Stainless steel 3cm long, 3mm in diameter
- For high precision measurements close to 0% O2
- Works in gas (%O2) and liquids (DO)
- No oxygen consumption
- Optically isolated (OI)
Trace Range Robust Oxygen Probe
TROXROB10
- Stainless steel 10cm long, 3mm in diameter
- For high precision measurements close to 0% O2
- Works in gas (%O2) and liquids (DO)
- No oxygen consumption
- Optically isolated (OI)
Robust Oxygen Dipping Probe
OPDIP20
- Stainless steel 20cm long, 3mm in diameter
- PICO-connector
- Works in gas (%O2) and liquids (DO)
- No oxygen consumption
- Optically isolated (OI)
Robust Oxygen Probe
OPROB3
- Stainless steel 3cm long, 3mm in diameter
- 1m fiber length, PICO-connector
- Works in gas (%O2) and liquids (DO)
- No oxygen consumption
- Optically isolated (OI)
Robust Oxygen Probe
OXROB10-CL4
- Stainless steel 10cm long, 3mm in diameter
- 4m cable length (CL4)
- Works in gas (%O2) and liquids (DO)
- Optically isolated (OI)
- Negligible drift, >3 years shelf time
Robust Screw Cap Oxygen Probe
OXROBSC-SUB
- Robust screw cap probe with 2 oxygen screw cap sensors
- Works in gas (%O2) and liquids (DO)
- No oxygen consumption
- Optically isolated (OI)
- With underwater connector (-SUB)
Robust Oxygen Probe
OXROB10-CL4-SUB
- Stainless steel 10cm long, 3mm in diameter
- 4m cable length (CL4)
- With underwater SUB-connector (SUB)
- Optically isolated (OI)
- Negligible drift, >3 years shelf time
Robust Oxygen Probe
OXROB3-CL4
- Stainless steel 3cm long, 3mm in diameter
- 4m cable length (CL4)
- Works in gas (%O2) and liquids (DO)
- Optically isolated (OI)
- Negligible drift, >3 years shelf time
Robust Oxygen Probe
OXROB3-SUB
- Stainless steel 3cm long, 3mm in diameter
- With underwater SUB-connector (SUB)
- No oxygen consumption
- Optically isolated (OI)
- Negligible drift, >3 years shelf time
Robust Oxygen Probe
OXROB3-CL4-SUB
- Stainless steel 3cm long, 3mm in diameter
- With underwater SUB-connector (SUB)
- 4m cable length (CL4)
- Optically isolated (OI)
- Negligible drift, >3 years shelf time
Fixed Fiber Oxygen Microsensor
OXF50-UHS
- Fixed sensor tip surrounded by needle
- Sensor tip protrudes ca. 6mm
- 50-70µm sharp sensor tip
- Ultra-high speed response time (t90 < 0.3s)
- Works in gas (%O2) and liquids (DO)
Fixed Fiber Oxygen Microsensor
OXF50-HS
- Fixed sensor tip surrounded by needle
- Sensor tip protrudes ca. 6mm
- 50-70µm sharp sensor tip
- High speed response time (t90 < 0.8s)
- Works in gas (%O2) and liquids (DO)
Fixed Fiber Oxygen Microsensor
OXF50-UHS-SUB
- Fixed sensor tip surrounded by needle
- Sensor tip protrudes ca. 6mm
- 50-70µm sharp sensor tip
- Ultra-high speed response time (t90 < 0.3s)
- With underwater SUB-connector (SUB)
Fixed Fiber Oxygen Microsensor
OXF50-OI
- Fixed sensor tip surrounded by needle
- Sensor tip protrudes ca. 6mm
- 50-70µm sharp sensor tip
- Optically isolated (OI)
- Works in gas (%O2) and liquids (DO)
Fixed Fiber Oxygen Microsensor
OXF50-SUB
- Fixed sensor tip surrounded by needle
- Sensor tip protrudes ca. 6mm
- 50-70µm sharp sensor tip
- With underwater SUB-connector (SUB)
- Negligible drift, >3 years shelf time
Fixed Fiber Oxygen Minisensor
OXF1100-UHS
- Fixed sensor tip surrounded by needle
- Sensor tip protrudes ca. 2mm
- Ultra-high speed response time (t90 < 0.3s)
- Works in gas (%O2) and liquids (DO)
- Negligible drift, >3 years shelf time
Fixed Fiber Oxygen Minisensor
OXF1100-UHS-SUB
- Fixed sensor tip surrounded by needle
- Sensor tip protrudes ca. 2mm
- Ultra-high speed response time (t90 < 0.3s)
- With underwater SUB-connector (SUB)
- Negligible drift, >3 years shelf time
Fixed Fiber Oxygen Minisensor
OXF1100-HS
- Fixed sensor tip surrounded by needle
- Sensor tip protrudes ca. 2mm
- High speed response time (t90 < 0.8s)
- Works in gas (%O2) and liquids (DO)
- Negligible drift, >3 years shelf time
Fixed Fiber Oxygen Minisensor
OXF1100-HS-SUB
- Fixed sensor tip surrounded by needle
- Sensor tip protrudes ca. 2mm
- High speed response time (t90 < 0.8s)
- With underwater SUB-connector (SUB)
- Negligible drift, >3 years shelf time
Fixed Fiber Oxygen Minisensor
OXF1100-CL4
- Fixed sensor tip surrounded by needle
- Sensor tip protrudes ca. 2mm
- 4m cable length (CL4)
- Works in gas (%O2) and liquids (DO)
- Negligible drift, >3 years shelf time
Fixed Fiber Oxygen Minisensor
OXF1100-OI
- Fixed sensor tip surrounded by needle
- Sensor tip protrudes ca. 2mm
- Optically isolated (OI)
- Works in gas (%O2) and liquids (DO)
- Negligible drift, >3 years shelf time
Fixed Fiber Oxygen Minisensor
OXF1100-SUB
- Fixed sensor tip surrounded by needle
- Sensor tip protrudes ca. 2mm
- With underwater SUB-connector (SUB)
- No oxygen consumption
- Negligible drift, >3 years shelf time
Bare Fiber Oxygen Minisensor
OXB430-UHS
- Optical fiber 430µm in diameter
- Ultra-high speed response time (t90 < 0.3s)
- Works in gas (%O2) and liquids (DO)
- No oxygen consumption
- Negligible drift, >3 years shelf time
Bare Fiber Oxygen Minisensor
OXB430-HS
- Optical fiber 430µm in diameter
- High speed response time (t90 < 0.8s)
- Works in gas (%O2) and liquids (DO)
- No oxygen consumption
- Negligible drift, >3 years shelf time
Bare Fiber Oxygen Minisensor
OXB430-HS-SUB
- Optical fiber 430µm in diameter
- High speed response time (t90 < 0.8s)
- With underwater SUB-connector (SUB)
- No oxygen consumption
- Negligible drift, >3 years shelf time
Bare Fiber Oxygen Minisensor
OXB430-UHS-SUB
- Optical fiber 430µm in diameter
- Ultra-high speed response time (t90 < 0.3s)
- With underwater SUB-connector (SUB)
- No oxygen consumption
- Negligible drift, >3 years shelf time
Bare Fiber Oxygen Microsensor
OXB50-UHS
- 50-70µm sharp sensor tip
- Ultra-high speed response time (t90 < 0.3s)
- Works in gas (%O2) and liquids (DO)
- No oxygen consumption
- Negligible drift, >3 years shelf time
Bare Fiber Oxygen Minisensor
OXB430-OI
- Optical fiber 430µm in diameter
- High speed response time (t90 < 0.8s)
- Optically isolated (OI)
- No oxygen consumption
- Negligible drift, >3 years shelf time
Bare Fiber Oxygen Microsensor
OXB50-HS
- 50-70µm sharp sensor tip
- High speed response time (t90 < 0.8s)
- Works in gas (%O2) and liquids (DO)
- No oxygen consumption
- Negligible drift, >3 years shelf time
Would you like to stay informed?